Click thumbnails to switch media. Click main image for fullscreen.
Bench Tested & Frequency Calibrated
Operating standard: EPC Gen2 / ISO 18000-6C at 865.0–867.0 MHz (WPC India). Every reader, antenna, and tag batch is verified for read sensitivity, return loss (S11), and firmware stability prior to Indian warehouse dispatch.
Fixed RFID Readers
Impinj R700 RAIN RFID Reader: Price in India, Specs & Stock
High-Performance Linux IoT RAIN RFID Reader with -92 dBm Sensitivity & Gigabit PoE+
Wholesale & custom volume pricing available. Get an instant quote below.
Low-latency Gen2 portal gateway reader filtering & REST webhooks.
Explore SDK, Docker & Integration Blueprint →Description
The Impinj Speedway R700 4-Port Enterprise RAIN RFID Reader (Model: PRD_IMPINJ_R700_4P) is the world's most advanced fixed RAIN RFID reader engineered for global supply chain logistics, automated dock-door portals, high-speed conveyor sorting, and enterprise retail inventory tracking. Powered by a high-performance Dual-Core 1 GHz processor with 1 GB RAM/Flash running an embedded Linux OS, the R700 delivers unmatched receive sensitivity of -92 dBm, enabling lightning-fast tag reading exceeding 1,100 tags per second.
1. High-Sensitivity RF Architecture & Gigabit PoE+ Power
The R700 features 4 monostatic RP-TNC antenna ports capable of driving up to 32 antennas via Impinj antenna hubs. Operating across 860 MHz to 960 MHz (including Indian WPC 865–867 MHz), its industry-leading -92 dBm sensitivity captures weak backscatter signals from small, densely packed tags at distances up to 15+ meters. Powered via Gigabit Ethernet PoE+ (802.3at), it eliminates the need for external DC power bricks in industrial ceiling and dock-door installations.
2. Edge Computing & Native IoT Cloud Protocols (REST / MQTT)
Unlike legacy readers that require bulky middleware servers, the Impinj R700 runs modern edge applications directly on the reader. It streams filtered, deduplicated RFID event payloads natively to cloud platforms (AWS IoT, Microsoft Azure, Google Cloud) via REST APIs, MQTT, WebSockets, and LLRP, drastically reducing network bandwidth and server processing loads.
Specifications
- Model Number
- IPJ-R700-4P (Impinj Speedway R700 Enterprise Fixed Reader)
- Antenna Ports
- 4 Monostatic RP-TNC Ports (Expandable up to 32 Antennas via Hubs)
- Receive Sensitivity
- -92 dBm (Industry-Leading RF Front-End)
- Max Output Power
- +30 dBm (1.0 Watt) Conducted Power
- Tag Read Rate
- 1,100+ Tags / Second (Dense Reader Mode)
- Operating Frequency
- 860 MHz to 960 MHz (Broadband Global UHF / WPC 865–867 MHz)
- Protocol Standard
- EPCglobal Gen2v2 / ISO/IEC 18000-63 (RAIN RFID) EPC Gen2 (ISO 18000-6C)Air Interface865–867EPC Gen2 & ISO/IEC 18000-63 (RAIN RFID)
The universal ultra-high frequency (UHF) passive radio backscatter standard powering global retail, logistics, and asset tracking.
View Protocol Code & Specs - Processor & Memory
- Dual-Core 1.0 GHz ARM Processor | 1 GB DDR4 RAM | 1 GB Flash
- Operating System
- Embedded Enterprise Linux OS with Custom On-Reader Container Support
- Network Connectivity
- 10/100/1000 BASE-T Gigabit Ethernet (RJ45)
- Power Options
- Power over Ethernet (PoE 802.3af / PoE+ 802.3at) or 12–24V DC Jack
- IoT Edge Protocols
- Native MQTT, REST API, WebSockets, LLRP, Kafka Stream Connectors LLRPReader & MiddlewareTCPLow Level Reader Protocol (LLRP v1.0.1 / v1.1)
The vendor-agnostic international binary protocol standard for controlling and streaming tag data from fixed UHF RFID readers.
View Protocol Code & Specs ✓ OpenRFIDMQTT & Sparkplug BReader & MiddlewareTCPMQTT & Sparkplug B IoT Telemetry ProtocolLightweight publish/subscribe protocol optimized for streaming real-time RFID reads from edge readers and smart lockers into enterprise cloud platforms.
View Protocol Code & Specs ✓ OpenRFID - GPIO Interface
- 4 Optically Isolated Inputs / 4 Optically Isolated Outputs (DB15)
- Ingress Protection
- IP50 Rated Rugged Cast Aluminum Enclosure
- Weight
- 1.50 kg (Shipping Weight: Impinj R700 Reader with Mounting Brackets & Power Adapter / Net: 0.96 kg)
Hardware SDK & Edge API Quickstart
Connect, configure RF power (10–33 dBm), and stream tag inventory to your ERP / backend in under 5 minutes.
using OpenRFID.Core.Drivers;
using OpenRFID.Core.Models;
// 1. Initialize TCP/LLRP Connection
using var cts = new CancellationTokenSource(TimeSpan.FromSeconds(30));
var reader = new OpenRfidClient(ip: "192.168.1.116", port: 5084);
await reader.ConnectAsync(cts.Token);
await reader.SetPowerAsync(antennaId: 1, txPowerDbm: 30.0); // India WPC 865-867 MHz
// 2. Stream Real-time RFID Inventory Events with Lock-Free Channel
await foreach (var tag in reader.StreamTagsAsync(cts.Token))
{
Console.WriteLine("[LIVE READ] EPC: " + tag.EpcHex + " | RSSI: " + tag.RssiDbm + " dBm");
// Dispatches directly to SAP / Tally / SQL Database queue
await erpBridge.PushBatchAsync(tag);
} Industrial GPIO Pinout & Modbus TCP Register Map
Hardware wiring specifications for connecting Impinj R700 RAIN RFID Reader: Price in India, Specs & Stock directly to optical photocell sensors, light stacks, and Siemens / Allen-Bradley PLCs.
Instead of keeping the RFID scanner running 24/7 (which overheats equipment and reads distant tags accidentally), a physical light beam sensor (photocell) tells the reader to scan only when a box arrives on the conveyor belt. If the box has a missing or wrong tag, the reader instantly trips a red light and signals a robotic arm or pneumatic pusher to divert the box.
- 1 Optical Beam Cut: Carton cuts photocell beam → GPI-1 transitions from 0V to +24V HIGH.
- 2 1,500ms Active Scan: Reader powers RF antenna array (30 dBm) and captures all tag EPCs inside the carton.
- 3 ERP Validation: If carton count matches ERP manifest, GPO-1 pulses for 200ms (Green Light / Belt Continues).
- 4 Defect Ejection: If tag count is incomplete, GPO-2 triggers pneumatic diverter to route carton to audit lane.
PLC Modbus TCP Register Memory Mapping (Siemens S7-1200 / Rockwell CompactLogix)
| Register Address | Data Type | Access | Description & PLC Interpretation |
|---|---|---|---|
| 40001 | UINT16 | Read-Only | Reader Status: 0=Idle, 1=Scanning Active, 2=Fault/Overheat |
| 40002 | UINT16 | Read-Only | Total Unique Tags Captured in Current Trigger Cycle |
| 40003–40008 | 6 x UINT16 | Read-Only | 96-bit Hex EPC Data of Primary Verified Tag |
| 40009 | INT16 | Read-Only | Peak Signal RSSI (e.g. -48 dBm) for RF coverage tuning |
| 40101 | UINT16 | Read/Write | PLC Software Trigger Override: Write 1 to start inventory cycle |
UHF RFID Read Range & Link Budget Estimator
Safe operational limit with multipath mitigation & antenna detuning buffer.
Maximum line-of-sight range in ideal non-metallic open air.
Verified Field Deployments & Technical Standards
Real customer results, companion bench video demonstrations, and official engineering setup documentation for Impinj R700 RAIN RFID Reader: Price in India, Specs & Stock.
Real-World Customer Deployments (1)
Interactive RFID Engineering Tools & Calculators
Use our free interactive calculators and simulators to model RF physics, calculate link budgets, estimate ROI, and configure EPC tags.
RFID Link Budget Calculator
Calculate reader EIRP (+36 dBm WPC), antenna gain (dBi), path loss, and receiver sensitivity threshold (-86 dBm).
Antenna Coverage & Beamwidth Calculator
Model 3dB azimuth/elevation beam footprints and coverage radii for warehouse dock doors and conveyor gates.
RFID Portal Velocity Calculator
Estimate tag dwell times, maximum conveyor transit speeds (m/s), and read rates under dense tag environments.
Questions
Why is the -92 dBm receive sensitivity of the Impinj R700 important for warehouse dock doors?
Can the Impinj R700 stream RFID scan data directly to AWS or Azure IoT without middleware?
How is the Impinj R700 powered in industrial ceiling or portal installations?
What is the HSN Code and GST rate for Impinj fixed RFID readers in India?
How many antennas can be connected to a single Impinj R700 reader?
Unit Price
₹1,25,000
Explore more
Related solutions, hardware specifications, and integration guides.

resource
How to Connect Impinj Speedway Readers to Computer via LAN
Guide to connecting UHF & HF RFID readers to PC over USB HID wedge, Virtual COM port & Ethernet LAN (LLRP). Includes driver setup & Python/C# code snippets.
View →

product
Impinj Speedway R700 High-Speed Dock Portal Middleware
Enterprise IoT middleware for Impinj Speedway R700 and R420 RFID readers. Directional pallet tracking, MQTT telemetry streams, and Octane SDK edge filtering.
View →
resource
RFID Conveyor Tunnel & High-Speed Portal Automation Guide
Watch demonstration of industrial RFID tunnel and conveyor scanning portal with 4-antenna cross-fire, photocell GPIO triggers, and RF absorber foam.
View →
video
RFID Reader Hardware LAN Setup & Network Controller Demo
Watch live demonstration of connecting industrial RFID reader and gate controller to laptop over Ethernet LAN and PC software.
View →