Noida RF Test Lab Certified 100% Pre-Dispatch Burn-In

Bench Tested & Frequency Calibrated

Operating standard: EPC Gen2 / ISO 18000-6C at 865.0–867.0 MHz (WPC India). Every reader, antenna, and tag batch is verified for read sensitivity, return loss (S11), and firmware stability prior to Indian warehouse dispatch.

Sensitivity ISO RF Verified
Warranty 1-Year Replacement
Support Free SDK & Drivers
Same-Week Noida Lab Dispatch

Fixed RFID Readers

Fixed RFID Reader (4-Port & 8-Port UHF) for Warehouses & Portals

Industrial 4-Port & 8-Port Fixed UHF RFID Reader | Impinj E710 / R2000 Engine & PoE+ Gigabit Gateway

✨Simple Explanation with AI Freq: 865.0 MHz to 867.0 MHz (Indian WPC Certified) / Global RAIN UHF
₹52,000 ★ 4.8

Wholesale & custom volume pricing available. Get an instant quote below.

1-Year OEM Warranty
LLRP & REST API Ready
Pan-India Dispatch
Multi-Port Power Tested

Description

Power your automated warehouse dock doors, production conveyor lines, and asset portals with our high-throughput Fixed RFID Readers. Available in 4-port and 8-port SMA/TNC configurations, these enterprise readers integrate genuine Impinj E710 / Indy R2000 transceiver engines to achieve lightning-fast read rates exceeding 1,000 tags per second with industry-leading -88 dBm receiver sensitivity. Housed in rugged die-cast aluminum enclosures and powered over a single Ethernet cable (PoE+ 802.3at), our readers eliminate complex external power drops while offering isolated GPIO ports to trigger light stacks, audible sirens, and conveyor diverters automatically.

Specifications

Model Number
PRD-FIXED-4P-UHF
Antenna Ports
4 Monostatic RP-TNC 50-Ohm Ports (Expandable)
RF Output Power
+10 dBm to +33 dBm (10mW to 2000mW) Software Adjustable
Receive Sensitivity
-88 dBm (High-Sensitivity Front-End)
Scan Throughput
1,000+ Tags / Second (Anti-Collision Dense Mode)
Operating Frequency
865.0 MHz to 867.0 MHz (Indian WPC Certified) / Global RAIN UHF
Protocol Standard
EPCglobal Gen2v2 / ISO/IEC 18000-63 (RAIN RFID)
EPC Gen2 (ISO 18000-6C)
Communication Interfaces
10/100/1000M Ethernet (RJ45), RS-232, RS-485, USB Type-B
Power Supply
Power over Ethernet Plus (PoE+ 802.3at) or 12V–24V DC / 3A Adapter
GPIO Interface
4 Optically Isolated Digital Inputs / 4 Relay Outputs (Terminal Block)
IoT Streaming Protocols
Native MQTT, REST API, WebSockets, LLRP v1.1, TCP/IP Raw Socket
LLRP
MQTT & Sparkplug B
Operating Temperature
-20°C to +60°C (-4°F to +140°F)
Housing Material
Industrial Die-Cast Aluminum Shielded Enclosure
Weight
1.80 kg (Shipping Weight: 4-Port Industrial Fixed Reader with GPIO & Power Brick / Net: 1.20 kg)
Factory Automation & Modbus PLC Integration →

Industrial GPIO Pinout & Modbus TCP Register Map

Hardware wiring specifications for connecting Fixed RFID Reader (4-Port & 8-Port UHF) for Warehouses & Portals directly to optical photocell sensors, light stacks, and Siemens / Allen-Bradley PLCs.

4 Opto Inputs 4 Relay Outputs
💡
How Factory Automation Works (In Plain English):

Instead of keeping the RFID scanner running 24/7 (which overheats equipment and reads distant tags accidentally), a physical light beam sensor (photocell) tells the reader to scan only when a box arrives on the conveyor belt. If the box has a missing or wrong tag, the reader instantly trips a red light and signals a robotic arm or pneumatic pusher to divert the box.

10-Pin Screw Terminal Pinout 2.5 kV Galvanic Isolation
PIN 1: GPI-1 (+)
Photocell Sensor Trigger (5–24V DC)
PIN 2: GPI-1 (-)
Isolated Ground Reference
PIN 5: GPO-1 (NO)
Green Light Stack Relay (Max 30V/1A)
PIN 6: GPO-2 (NO)
Red Siren / Diverter Ejector Relay
PINS 9 & 10: AUX +24V DC / GND
Internal auxiliary power output for powering proximity sensors
Conveyor Trigger Logic Workflow
  1. 1 Optical Beam Cut: Carton cuts photocell beam → GPI-1 transitions from 0V to +24V HIGH.
  2. 2 1,500ms Active Scan: Reader powers RF antenna array (30 dBm) and captures all tag EPCs inside the carton.
  3. 3 ERP Validation: If carton count matches ERP manifest, GPO-1 pulses for 200ms (Green Light / Belt Continues).
  4. 4 Defect Ejection: If tag count is incomplete, GPO-2 triggers pneumatic diverter to route carton to audit lane.
⚡ Cycle Execution Time: < 45 milliseconds

PLC Modbus TCP Register Memory Mapping (Siemens S7-1200 / Rockwell CompactLogix)

Register Address Data Type Access Description & PLC Interpretation
40001 UINT16 Read-Only Reader Status: 0=Idle, 1=Scanning Active, 2=Fault/Overheat
40002 UINT16 Read-Only Total Unique Tags Captured in Current Trigger Cycle
40003–40008 6 x UINT16 Read-Only 96-bit Hex EPC Data of Primary Verified Tag
40009 INT16 Read-Only Peak Signal RSSI (e.g. -48 dBm) for RF coverage tuning
40101 UINT16 Read/Write PLC Software Trigger Override: Write 1 to start inventory cycle
Friis Transmission Physics & WPC 865–867 MHz

UHF RFID Read Range & Link Budget Estimator

10 dBm (Handheld Low)27 dBm (Handheld High)30 dBm (Standard Fixed)33 dBm (Max Port)
5m (0.64 dB Loss)
Calculated Range & Link Metrics
Recommended Working Distance (Warehouse Reliability 99.5%):
8.5m(28.0 Feet)

Safe operational limit with multipath mitigation & antenna detuning buffer.

Theoretical Free-Space Maximum:
12.2m(40.0 Feet)

Maximum line-of-sight range in ideal non-metallic open air.

Total Radiated EIRP:38.4 dBm (6.85 W)
WPC Legal Ceiling (India):36.0 dBm (4.0 W EIRP)
Coaxial Cable Attenuation:-0.64 dB
Forward Link Margin:+60.9 dB
ℹ️All fixed readers deployed by RFID Softwares hold certified WPC Equipment Type Approval (ETA) for 865–867 MHz operation.

Verified Reviews

4.8out of 5

Based on 4 verified client reviews.

Genuine Enterprise Feedback
Verified Project Deployments
Deepak Sharma, Co-Founder at My IT Solutions (admis.co) Verified Project

"Incredibly rugged reader. The 4-port setup allows us to monitor multiple assembly zones from a single unit."

Rajesh Chhabra, Director at Waytm (waytm.in) Verified Project

"Outstanding read rates. Successfully captures high-speed pallet tags passing through our warehouse dock doors."

Gaurav Singh, Director at Gen Agri Parts (genagriparts.com) Verified Project

"Very easy to configure via the LLRP protocol. Integrates cleanly with our local inventory database."

Anand Verma, IT Director at SmartLogistics Corp Verified Project

"Power over Ethernet (PoE+) support made installation super clean without extra power cabling."

Questions

What frequency do fixed UHF RFID readers use in India?
Most fixed reader deployments in India use RAIN UHF in the WPC-aligned 865-867 MHz band (ISO 18000-6C / EPC Gen2). The exact configuration (power levels, antennas, and read zones) is tuned per site to avoid cross-reads and missed reads.
How fast can a fixed reader read tags (tags/second)?
In practical portal and tunnel workflows, fixed readers are commonly designed to handle around 100 tags/second, depending on tag quality, antenna geometry, item density, and zone tuning. The right KPI is not peak reads, but clean, reliable business events for receiving, shipping, and audits.
How does middleware help with stock updates?
Middleware converts raw EPC reads into stable inventory events by de-duplicating reads, applying confidence thresholds, and mapping tags to SKUs/assets. Once normalized, events can update stock automatically when products come into inventory (receiving) or go out (dispatch), including transfers and cycle counts.
Can fixed readers be used for anti-theft and alarms?
Yes. Fixed readers can support anti-theft workflows by combining read zones with GPIO triggers and a customized application. If a tagged product exits a controlled zone without a matching billing/dispatch event, the application can trigger an alarm, send notifications, and create an audit record for investigation.
Can we do real-time tracking with scheduled reads (10 min / 20 min / hourly)?
Yes. Many teams run interval-based inventory checks where fixed readers scan zones on a schedule (for example every 10 minutes, 20 minutes, or 1 hour) and reconcile the observed tags with expected stock. This improves real-time visibility and reduces manual cycle-count workload.
What are real-world use cases for fixed RFID readers?
Common use cases include warehouse receiving/dispatch portals, small shops improving stock accuracy, and conveyor/tunnel verification for packing. They can also be used in controlled environments for employee/person tracking, automated student attendance at entry points, hospitals for patient and equipment visibility, and high-security facilities (for example jails) using durable hard tags with strict read zones.
How do fixed readers support automatic inventory entry/exit?
Fixed readers are installed at choke points (receiving doors, dispatch lanes, store exits) and the middleware decides which reads count as an entry or an exit. Those validated events can post to ERP/WMS as receipts, shipments, transfers, or adjustments with audit logs.
What specifications should you compare for fixed readers?
Compare UHF band compliance for India (865-867 MHz), antenna port count (4-port is common), network interfaces, GPIO support, and integration method (LLRP/SDK). Also compare commissioning and tuning support, because read-zone design determines reliability more than any single datasheet number.

Explore more

Related solutions, hardware specifications, and integration guides.

Hi, Can I Help ? 💬
AI