Noida RF Test Lab Certified 100% Pre-Dispatch Burn-In

Bench Tested & Frequency Calibrated

Every hardware reader and handheld is tested for RF sensitivity, power output, and GPIO triggering at our Noida facility. Fully calibrated for India WPC 865.0–867.0 MHz with test certificate.

Enterprise Hardware Standards & Deliverables

WPC India Approved
865–867 MHz WPC India ETA
ISO 18000-6C EPC Class 1 Gen 2
PoE+ & GPIO Industrial I/O
Same-Week Noida Lab Dispatch

Fixed RFID Readers

Fixed RFID Reader India and UHF 4-Port Reader Portals

Four-port readers for portals and lines

✨Simple Explanation with AI Freq: 865.0 MHz to 867.0 MHz (Indian WPC Certified) / Global RAIN UHF
₹52,000 ★ 4.8

Wholesale & custom volume pricing available. Get an instant quote below.

Enterprise Assurances

1-Year OEM Warranty
LLRP & REST API Ready
Pan-India Dispatch
Multi-Port Power Tested

Need Edge Reader Middleware or ERP Sync?

Eliminate tag flooding. We engineer edge middleware daemons that filter tag reads locally and post automated Goods Receipt & Dispatch vouchers into SAP or Tally Prime.

Description

The Fixed RFID Reader India and UHF 4-Port Reader Portals (Model: PRD_HW_FIXED) are high-performance enterprise fixed RAIN RFID reader systems engineered for automated warehouse dock doors, conveyor belt item sorting, automated parking gates, and factory floor Work-in-Progress (WIP) tracking. Powered by the Impinj E710 / R2000 multi-protocol silicon IC, this 4-port reader delivers industry-leading receive sensitivity of -88 dBm and an ultra-fast scan rate of over 1,000 tags per second.

1. 4 Monostatic RP-TNC Ports & High-Power RF Physics

Operating across 860 MHz to 960 MHz (tuned for Indian WPC 865–867 MHz with output power up to +33 dBm / 2 Watts), the reader drives up to 4 external circular-polarized antennas, creating high-density dock-door RF portals that scan packed shipping pallets moving on forklifts at speeds up to 20 km/h with 99.9%+ read accuracy.

2. Industrial GPIO Automation & IoT Cloud Connectivity

Housed in a rugged die-cast aluminum enclosure with IP54 industrial protection, the reader includes 4 optically isolated digital inputs and 4 relay outputs (GPIO) to trigger photo-eye sensors, warning light stacks, and motorized conveyor diverter gates. It supports Gigabit Ethernet PoE+, RS232/RS485, USB, and native MQTT/REST API streaming directly to enterprise ERP systems (SAP, Oracle, Microsoft Dynamics).

Specifications

Model Number
PRD-FIXED-4P-UHF
Antenna Ports
4 Monostatic RP-TNC 50-Ohm Ports (Expandable)
RF Output Power
+10 dBm to +33 dBm (10mW to 2000mW) Software Adjustable
Receive Sensitivity
-88 dBm (High-Sensitivity Front-End)
Scan Throughput
1,000+ Tags / Second (Anti-Collision Dense Mode)
Operating Frequency
865.0 MHz to 867.0 MHz (Indian WPC Certified) / Global RAIN UHF
Protocol Standard
EPCglobal Gen2v2 / ISO/IEC 18000-63 (RAIN RFID)
EPC Gen2 (ISO 18000-6C)
Communication Interfaces
10/100/1000M Ethernet (RJ45), RS-232, RS-485, USB Type-B
Power Supply
Power over Ethernet Plus (PoE+ 802.3at) or 12V–24V DC / 3A Adapter
GPIO Interface
4 Optically Isolated Digital Inputs / 4 Relay Outputs (Terminal Block)
IoT Streaming Protocols
Native MQTT, REST API, WebSockets, LLRP v1.1, TCP/IP Raw Socket
LLRP
MQTT & Sparkplug B
Operating Temperature
-20°C to +60°C (-4°F to +140°F)
Housing Material
Industrial Die-Cast Aluminum Shielded Enclosure
Developer Integration Kit

Hardware SDK & Edge API Quickstart

Connect, configure RF power (10–33 dBm), and stream tag inventory to your ERP / backend in under 5 minutes.

Protocol
LLRP / RS-232 / REST
Read Rate
Up to 750 tags/sec
💡
Why this matters to your business: You are not locked into proprietary software. Our open integration drivers allow your internal IT team or ERP vendor (SAP, Tally, Zoho, Oracle) to directly ingest live RFID scans without expensive recurring middleware licensing fees.
RfidReaderIntegration.cs
API Ready
using OpenRFID.Core.Drivers;
using OpenRFID.Core.Models;

// 1. Initialize TCP/LLRP Connection
using var cts = new CancellationTokenSource(TimeSpan.FromSeconds(30));
var reader = new OpenRfidClient(ip: "192.168.1.116", port: 5084);

await reader.ConnectAsync(cts.Token);
await reader.SetPowerAsync(antennaId: 1, txPowerDbm: 30.0); // India WPC 865-867 MHz

// 2. Stream Real-time RFID Inventory Events with Lock-Free Channel
await foreach (var tag in reader.StreamTagsAsync(cts.Token))
{
    Console.WriteLine("[LIVE READ] EPC: " + tag.EpcHex + " | RSSI: " + tag.RssiDbm + " dBm");
    
    // Dispatches directly to SAP / Tally / SQL Database queue
    await erpBridge.PushBatchAsync(tag);
}
Factory Automation & Modbus PLC Integration →

Industrial GPIO Pinout & Modbus TCP Register Map

Hardware wiring specifications for connecting Fixed RFID Reader India and UHF 4-Port Reader Portals directly to optical photocell sensors, light stacks, and Siemens / Allen-Bradley PLCs.

4 Opto Inputs 4 Relay Outputs
💡
How Factory Automation Works (In Plain English):

Instead of keeping the RFID scanner running 24/7 (which overheats equipment and reads distant tags accidentally), a physical light beam sensor (photocell) tells the reader to scan only when a box arrives on the conveyor belt. If the box has a missing or wrong tag, the reader instantly trips a red light and signals a robotic arm or pneumatic pusher to divert the box.

10-Pin Screw Terminal Pinout 2.5 kV Galvanic Isolation
PIN 1: GPI-1 (+)
Photocell Sensor Trigger (5–24V DC)
PIN 2: GPI-1 (-)
Isolated Ground Reference
PIN 5: GPO-1 (NO)
Green Light Stack Relay (Max 30V/1A)
PIN 6: GPO-2 (NO)
Red Siren / Diverter Ejector Relay
PINS 9 & 10: AUX +24V DC / GND
Internal auxiliary power output for powering proximity sensors
Conveyor Trigger Logic Workflow
  1. 1 Optical Beam Cut: Carton cuts photocell beam → GPI-1 transitions from 0V to +24V HIGH.
  2. 2 1,500ms Active Scan: Reader powers RF antenna array (30 dBm) and captures all tag EPCs inside the carton.
  3. 3 ERP Validation: If carton count matches ERP manifest, GPO-1 pulses for 200ms (Green Light / Belt Continues).
  4. 4 Defect Ejection: If tag count is incomplete, GPO-2 triggers pneumatic diverter to route carton to audit lane.
⚡ Cycle Execution Time: < 45 milliseconds

PLC Modbus TCP Register Memory Mapping (Siemens S7-1200 / Rockwell CompactLogix)

Register Address Data Type Access Description & PLC Interpretation
40001 UINT16 Read-Only Reader Status: 0=Idle, 1=Scanning Active, 2=Fault/Overheat
40002 UINT16 Read-Only Total Unique Tags Captured in Current Trigger Cycle
40003–40008 6 x UINT16 Read-Only 96-bit Hex EPC Data of Primary Verified Tag
40009 INT16 Read-Only Peak Signal RSSI (e.g. -48 dBm) for RF coverage tuning
40101 UINT16 Read/Write PLC Software Trigger Override: Write 1 to start inventory cycle
Friis Transmission Physics & WPC 865–867 MHz

UHF RFID Read Range & Link Budget Estimator

10 dBm (Handheld Low)27 dBm (Handheld High)30 dBm (Standard Fixed)33 dBm (Max Port)
5m (0.64 dB Loss)
Calculated Range & Link Metrics
Recommended Working Distance (Warehouse Reliability 99.5%):
8.5m(28.0 Feet)

Safe operational limit with multipath mitigation & antenna detuning buffer.

Theoretical Free-Space Maximum:
12.2m(40.0 Feet)

Maximum line-of-sight range in ideal non-metallic open air.

Total Radiated EIRP:38.4 dBm (6.85 W)
WPC Legal Ceiling (India):36.0 dBm (4.0 W EIRP)
Coaxial Cable Attenuation:-0.64 dB
Forward Link Margin:+60.9 dB
ℹ️All fixed readers deployed by RFID Softwares hold certified WPC Equipment Type Approval (ETA) for 865–867 MHz operation.
Packaging & Accessories

What's in the Box & Hardware Blueprint

Every unit is factory-inspected, serialized, and paired with essential deployment accessories.

Fixed Industrial Portal / Conveyor Gateway
01

Industrial Fixed Reader Hub (4/8 Port)

1 Unit

IP53/IP65 aluminum chassis with PoE+ support

02

24V 3.0A Regulated Power Supply & Cord

1 Set

Universal AC input with surge protection

03

LMR-240 Double-Shielded RF Cables (3m)

4 Cables

Ultra-low attenuation SMA-Male to RP-TNC Male

04

Heavy-Duty Aluminum VESA Mounting Kit

1 Set

Vibration-damped bracket for portal masts

05

Opto-Isolated GPIO Terminal Block

1 Block

Plug for photocell beam sensors & light stack relays

06

OpenRFID Edge Daemon License (1-Year)

1 License

Native SAP RFC, Tally XML & LLRP bridge

💡

Need a 14-Day Physical On-Site Pilot Evaluation?

We offer paid 14-day on-site pilot trials with demo setup in Delhi-NCR (minimum ~₹50,000+ demo POC fee + refundable hardware deposit). Remote-assisted starter packs available across India.

Book Paid Pilot Trial

Verified Reviews

4.8out of 5

Based on 4 verified client reviews.

Genuine Enterprise Feedback
Verified Project Deployments
Deepak Sharma, Co-Founder at My IT Solutions (admis.co) Verified Project

"Incredibly rugged reader. The 4-port setup allows us to monitor multiple assembly zones from a single unit."

Rajesh Chhabra, Director at Waytm (waytm.in) Verified Project

"Outstanding read rates. Successfully captures high-speed pallet tags passing through our warehouse dock doors."

Gaurav Singh, Director at Gen Agri Parts (genagriparts.com) Verified Project

"Very easy to configure via the LLRP protocol. Integrates cleanly with our local inventory database."

Anand Verma, IT Director at SmartLogistics Corp Verified Project

"Power over Ethernet (PoE+) support made installation super clean without extra power cabling."

Questions

What frequency do fixed UHF RFID readers use in India?
Most fixed reader deployments in India use RAIN UHF in the WPC-aligned 865-867 MHz band (ISO 18000-6C / EPC Gen2). The exact configuration (power levels, antennas, and read zones) is tuned per site to avoid cross-reads and missed reads.
How fast can a fixed reader read tags (tags/second)?
In practical portal and tunnel workflows, fixed readers are commonly designed to handle around 100 tags/second, depending on tag quality, antenna geometry, item density, and zone tuning. The right KPI is not peak reads, but clean, reliable business events for receiving, shipping, and audits.
How does middleware help with stock updates?
Middleware converts raw EPC reads into stable inventory events by de-duplicating reads, applying confidence thresholds, and mapping tags to SKUs/assets. Once normalized, events can update stock automatically when products come into inventory (receiving) or go out (dispatch), including transfers and cycle counts.
Can fixed readers be used for anti-theft and alarms?
Yes. Fixed readers can support anti-theft workflows by combining read zones with GPIO triggers and a customized application. If a tagged product exits a controlled zone without a matching billing/dispatch event, the application can trigger an alarm, send notifications, and create an audit record for investigation.
Can we do real-time tracking with scheduled reads (10 min / 20 min / hourly)?
Yes. Many teams run interval-based inventory checks where fixed readers scan zones on a schedule (for example every 10 minutes, 20 minutes, or 1 hour) and reconcile the observed tags with expected stock. This improves real-time visibility and reduces manual cycle-count workload.
What are real-world use cases for fixed RFID readers?
Common use cases include warehouse receiving/dispatch portals, small shops improving stock accuracy, and conveyor/tunnel verification for packing. They can also be used in controlled environments for employee/person tracking, automated student attendance at entry points, hospitals for patient and equipment visibility, and high-security facilities (for example jails) using durable hard tags with strict read zones.
How do fixed readers support automatic inventory entry/exit?
Fixed readers are installed at choke points (receiving doors, dispatch lanes, store exits) and the middleware decides which reads count as an entry or an exit. Those validated events can post to ERP/WMS as receipts, shipments, transfers, or adjustments with audit logs.
What specifications should you compare for fixed readers?
Compare UHF band compliance for India (865-867 MHz), antenna port count (4-port is common), network interfaces, GPIO support, and integration method (LLRP/SDK). Also compare commissioning and tuning support, because read-zone design determines reliability more than any single datasheet number.

Explore more

Related solutions, hardware specifications, and integration guides.

Hi, Can I Help ? 💬